THE "ISSUES" WITH HEIGHT GAGES
George Schuetz, Mahr Federal Inc.

Don't tell any one, but there is something of a problem with height gages.  The big issue that they have is what they measure, height.  The larger the height gage, the bigger the potential problem.

It's not actually the height that is the problem.  It's the relationship of a large height to the small base.  Just like a lever—the longer the arm, the larger the multiplying factor—and with a height gage this is the problem.  We are not only talking about the errors coming from the gage itself, but also errors in the setup.  These get magnified and can potentially distort an otherwise carefully planned comparison.

A major error in the design of a basic height gage is taking a design that was meant to measure 12" and simply extending the post to measure 36", without changing the base design or the cross-area of the measuring post.  What then naturally happens is that the gage will tend to wobble and flex.  Although you may not be able to see the 0.001" wobble, it can become a significant part of the part tolerance and certainly influence the measurement.

A normal step in trying to increase the performance of the gage is to beef up the column in an attempt to reduce the flexure of the post.  However, this only gets us part of the way to a better gage.  For example, if a slight pressure is placed horizontally against the gage's measuring contact, the gage may slide along the table.  If the same force is applied to the measuring contact when it is near its maximum upper position, this force will very likely cause the gage to tip over.  What needs to be done is make the base longer and wider, and build in some mass.  By decreasing the ratio of the post to the base there will be significant improvement in its performance.


Besides its own personal issues, the height gage tends to keep company with tools having bad references.  Most height gages are used with a surface plate.  The surface plate provides the reference for the part and the height gage.  Many surface plates are clean and well maintained.  But there are those that may not be as clean as they look.  A small metal chip or even a hair, while almost impossible to see, could throw off the measurement by 0.020" at a height of only 10".

Next to dirt, the actual surface of the granite surface plate will play a key role in the performance of the gage.  Any slight imperfection between where the part and the gage are staged will get amplified the higher the measurement.  Most surface plates have a flatness spec of 50µ".  If the base is say 6" long, a 50µ" error would grow to more than 0.0003" in 36", and even worse if the plate is out of spec.