Technika pomiarowa
Technika pomiarowa
Millimar EMD-832P-48-W2 Elektroniczny system poziomic do pomiarów metodą różnicową
PL
  • Compare the orientation attitude of separate or adjacent horizontal surfaces
  • Level systems are angular-linear compatible
  • Sensing heads are interchangeable with Federal electrical spec.'s gageheads to accommodate linear measurements
  • Fast response: quick response to slight angular changes permit taking fast and accurate measurements at various sensing head positions or taking dynamic position readings
  • Resolution/Repeatability: Mahr Federal’s Electronic Levels far exceed the sensitivity and accuracy of precision spirit levels with a resolution to 6 μin per foot (.1 arc second), compared to the spirit level’s resolution of .0001“ per foot. With repeatability at ±.1 arc second, Electronic Levels are ideal for ultra-high resolution profiling.
  • Direct dimensional readout: multiplier feature permits operator to view displacement caused by the angular measurement of the level head; this is displayed as an inches per foot readout rather than arc seconds; eliminates readout confusion when switching from spirit levels to electronic levels
  • Angular-linear compatible: sensing heads are easily interchangeable with Federal electrical spec.'s gageheads to accommodate linear measurements
  • Electronic levels are much easier to use with an autocollimator or a laser based calibration system
  • Performance is comparable and results are obtained without time consuming sight path alignments, cleaning of sensitive optical surfaces or hard to control environmental conditions
  • The differential level system operates simultaneously with a single amplifier, permitting an immediate comparison between two surfaces
  • Adjustable bases permit setup on surfaces that are out-of-level or square by as much as ± 1.5°
  • Dane techniczne

Nr kat.Typ produktuZakres wskazań wskaźnika cyfrowego µmZakres wskazań wskaźnika cyfrowego caleRozdzielczość µmRozdzielczość arc secRozdzielczość radWskaźnik tolerancjiWejścia czujnikówZgodnośćFunkcje dynamiczneKlasyfikacjaZłącze danychWejścia sterująceWyjścia sterująceWyjście analogoweZasilanie
2120550
EMD-832P-48-W1
± 2000 / ± 200 / ± 20
± .100" / ± .010" / ± .001"
1 / 0,1 / 0,02
0,1 arc sec / 1 arc sec
0,005 mrad / 0,0005 mrad
LED, 5 Class
2
Federal
Maks., min., TIR, nominalny
5
RS-232C
3
5
±5Vdc
Akumulator, 10 h przy pełnym obciążeniu lub 120 VAC / 240 VAC 50 - 60 Hz przez zasilacz wtyczkowy
2120551
EMD-832P-48-W2
± 2000 / ± 200 / ± 20
± .100" / ± .010" / ± .001"
1 / 0,1 / 0,02
0,1 arc sec / 1 arc sec
0,005 mrad / 0,0005 mrad
LED, 5 class
2
Federal
Maks., min., TIR, nominalny
5
RS-232C
3
5
±5Vdc
Tryb baterii / 230 V/50 Hz